Page tree



Skip to end of metadata
Go to start of metadata

ThinOX V10 ver. 10.1.11

Supported Models

Supported models are: 

  • A9054
  • U9054
  • D9054
  • A9050
  • U9050
  • U9200
  • C9200
  • C9050
  • C9010
  • D90-HOR, A90-HOR, U90-HOR, N90-HOR

  • D90-RFX, A90-RFX, U90-RFX, N90-RFX

  • D90-HDX, A90-HDX, U90-HDX, N90-HDX

Important Notes

IMPORTANT - Upgrading to this version needs ThinMan 7.5.x

The new format of the ThinOX firmware is installable and manageable by the ThinMan management software version 7.5.0 or higher.

Please download and update the ThinMan Server to the version 7.5.0 and afterwards proceed with upgrade of the Thin Clients.

The new format of ThinOX firmware is not installable by previous versions of ThinMan (e.g. ThinMan 7.4.x or 7.3.x).

READ CAREFULLY

IMPORTANT NOTE for ThinOX Ver. 10.1.1 
THE UPGRADE (from version 8.x or 9.x) WILL FORCE THE DEVICE TO FACTORY DEFAULT

Dear Customer,

This new version includes significant improvements and changes to the product. By performing this upgrade the Thin Client will be forced to Factory Default.

This process will delete the previous configuration and you will be asked to configure the device again.

Before starting the upgrade, please read carefully the FAQ section and the related firmware information available at the following link:

IMPORTANT - Upgrade to 10.0.x from older firmware version

Note about Energy Star 6.1

Note that with the new Energy Star 6.1 compliance a factory default device will enter the "Suspend" mode after 30 minutes of inactivity. You can change this behavior using the "Power Management" applet in the "Control Panel" (link: Power Management).


Release Notes


Issue IDTypeFromDescription
TCTX-1818Improvement10.1.11Added support for monitor resolution 1152x864.
TCTX-1808Fix10.1.11Certificate Manager: the certificates added here are not available in browser connection (Firefox).
TCTX-1801Fix10.1.11Some fix in the Wi-Fi configuration file used for WEP modality.
TCTX-1800Fix10.1.11Better information in the "Firmware" tab inside the "Properties" window.
TCTX-1795Improvement10.1.11Added support for USB EvTek headphones.
TCTX-1794Fix10.1.10Certificates sent through a template are not correctly used by the device.
TCTX-1792Improvement10.1.11The device send to ThinMan (vers. 7.5.7 and above) the list of the AddOns installed on itself.
TCTX-1780Fix10.1.8C9050 with VMware Connection: the reproduced audio is not at the best quality (distorted).
TCTX-1777Improvement10.1.11Serial Port: added "Flow Control" parameter on the Serial Port configurator.
TCTX-1764Fix10.1.9HDX RealTime Optimization Pack 2.1.200 once enabled cannot be disable from ICA Global Settings.
TCTX-1733Fix10.1.10The copy from RDP connection and paste on TN5250 video connection is not working.
TCTX-1724Fix10.1.11WBT Mode: the RDP Connection windows is not bring to front if clicked by the mouse (ALT+TAB is working correctly).
TCTX-616Alert10.1.11The VMware connection to Horizon View ver. 5.x could have some visualization problem.

Known Issues

Change password on RDP with NLA Authentication

RDP with NLA does not support the change password when it is expired. It cannot be solved. See more information on How to manage the change password request on RDP protocol with NLA authentication.


UNSUPPORTED PERIPHERALS

A list of unsupported peripherals for ThinOX 10 O.S.:

  • BusinessKeyINFOCERT(Realtek Semiconductor Corp.) with Vid:0bda Pid:0169
  • SISS cards are not supported on KUS0916 keyboard



Issue IDTypeDescription
TCTX-2047FixIf the ThinMan Agent is disabled the device will not shutdown.
TCTX-1980FixIBM iAccess: long session or printer names will cause an error on ThinMan.
TCTX-1916FixCUPS: if there are two different USB Printer configured in CUPS, the Test Printer Page is printed always on the last created printer.
TCTX-1883FixCUPS printing on LPT1 is not working.
Workaround: select the COM2 to print on LPT1.
TCTX-1871FixCertificates: it fails to import of certificate files with character "space" in the filename.
Workaround: rename the certificate files without character space on it.
TCTX-1865FixXenApp Services: reconnect session on exit is not working correctly.
TCTX-1836FixVMware Horizon View: smart-card login with Safenet token is not working.
TCTX-1834FixWith ThinMan Login enabled the hotkey combination <WIN>+<L> does not lock the session.
TCTX-1833FixVMware Horizon View Client: smart-card login is not working.
TCTX-1819FixN9050 with VMware Connection: the reproduced audio is not at the best quality (distorted).
TCTX-1815FixXenApp Plugin (ICA Client): application is not starting fullscreen but in windowed mode.
TCTX-1808FixCertificate Manager: the certificates added here are not available in browser connection (Firefox).
TCTX-1805FixWhen the device in under Remote Assistance by ThinMan and a network restarting is needed (e.g. changing IP from static to DHCP and viceversa) the "Restarting Network" message remain displayed on the device.
TCTX-1788FixC9050: VESA Video modality is not working correctly (do not show the desktop).
Workaround: use ThinMan "Configuration -> Receive", then modify the VESA configuration and use "Configuration -> Send" to reconfigure the device.
TCTX-1771FixC9050 with Citrix Connection: Windows Media Player redirection is not working.
TCTX-1611FixIn some cases "Ctrl + F4" do not close the Citrix Receiver Web Connection.
TCTX-1593FixThe Smart Card Reader model miniLECTOR 38 PR by Bit4id (Vid:0BDA, Pid:0169) is not currently supported.
TCTX-1113FixDuring Remote Assistance session the power off window (the one with the power management buttons) is not shown.
TCTX-866FixPraim Emulator: switch session button are not working correctly.
TCTX-862FixCitrix receiver: switching from "Legacy" Receiver to 13.x will lost configuration of dual monitor.
Workaround: execute a factory reset of the device and re-create the Citrix Connection.
TCTX-857FixU9050: the dual monitor configuration with Primary monitor connected to DVI-I and secondary monitor connected on VGA is not working correctly.
Workaround: user Primary monitor on VGA and Secondary monitor on DVI-I.
TCTX-837FixRDWeb App: when configuring a RemoteApp, the mouse focus is displaced in all applications.
TCTX-836FixRDWeb: credentials are requested every time a new app is launched.
TCTX-801FixShell Connection: the Shell connection is empty when applied to a device using the Profile Manager.
Workaround: use the manual configuration to send Shell connections.
TCTX-793FixU9200 with multimonitor and Citrix Receiver configured with only one monitor: the connection starts but is not usable.
TCTX-745FixVMware connection with RDP Protocol: the Large Screen property is not working correctly (the desktop is visualized in the center of the screen without window frame).
TCTX-724FixCitrix Receiver PNAgent: ending the connection with the Connections Manager will not close the session.
TCTX-662FixCitrix Receiver (PNAgent) with Published Desktop in "Stretched" multimonitor modality: the Desktop will occupy only the first monitor and the taskbar is present.
TCTX-659FixVMware Horizon View with RDP protocol on Windows 8 Virtual Desktop: the MMR feature is not working correctly.
TCTX-653AlertThe Citrix Receiver using the Self Service User Interface (SSUI) cannot be closed in full-screen mode.
Workaround: reboot the thin client to close the connection or use the ThinMan Console to modify the thin client configuration.
TCTX-649FixWBT User Interface with shortcut switcher "wbt mode": when using a RDP connection (protocol ver. 7) the hotkey CTRL + ALT + "home" or "UpArrow" or "DownArrow" does not switch between the sessions.
Workaround: use RDP protocol ver. 8.
TCTX-618FixVMware Horizon View with RDP protocol and dual monitor configuration is not working correctly.
TCTX-589AlertRDP8 in fullscreen multi monitor: is not working correctly with monitors with different resolutions.
Workaround: use the same resolution on both monitors.
TCTX-576FixRemote Assistance: when a RDP Connection ver. 7 is active, some keys are not working (e.g. "(" ).
TCTX-533FixC9010, C9050, C9200: using RDP8 RemoteFX on Server 2008 R2 can produce unexpected results when scrolling down large page of selected data (e.g. selection of 200 cells in MS Excel will not stop the scrolling).
TCTX-360FixThinMan Offline Configuration: the CUPS printer "Generic - Generic Text only" is not available in the printer setup configurator.
TCTX-176FixThe local Slovenian Keyboard Layout miss some character ('s', 'c', 'd', 'z' with caron and diacritic). When the connection is established, the layout is working correctly in the remote desktop/application.
TCTX-95AlertCitrix Receiver: Delphi written applications once minimized cannot be restored. It is a Citrix known limit.
Workaround: do not minimize application written in Delphi.
TCTX-94FixXenApp Agent: moving the window of a Delphi application causes the minimization of the window itself.
TCTX-46FixNetwork Configuration: Network and Broadcast parameters are maintained when switching from Static IP to DHCP configuraton mode.